كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A
كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A
  • كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A
  • كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A

كابل إسقاط FTTH متصل مسبقًا عالي الجودة مع ألياف G652D / G655 / G657A ، تم إنهاء المصنع للنشر السريع ، ومناسب لتركيبات FTTH الداخلية / الخارجية.
  • Factory pre-terminated connectors ensure fast and reliable installation.

  • Available with G652D, G655. or G657A fibers for various bending and distance requirements.

  • Supports SC/FC/LC connectors and customizable fiber lengths.

  • Compact, lightweight design for easy handling and routing.

  • Low insertion loss and high return loss for stable transmission.

What is Pre-Connected FTTH Drop Cable

Pre-Connected FTTH Drop Cable is a plug-and-play optical cable solution that pre-terminates connectors within the factory. It uses G652D, G655. or G657A fibers to meet different bending and transmission distance requirements, fundamentally eliminating on-site splicing, significantly shortening installation time, and improving the reliability of fiber-to-the-home networks. It is typically available in 1-core or 2-core specifications, supporting various connector types such as SC/APC, SC/UPC, FC, LC, and can be customized as needed. The outer sheath offers options for low smoke halogen-free (LSZH), PVC, or PE, catering to both indoor and outdoor environments. With its compact and lightweight structure, low insertion loss, and high return loss, this cable is easy to deploy and route management, ensuring stable transmission performance. It is widely used for fast fiber deployment in FTTH indoor and outdoor access, residential and small office networks, making it an ideal choice for last-mile connection and introductory installation.

Pre-Connected FTTH Drop Cable مواصفات المعلمات

المواصفات

البندالبيانات
طول قطع الكابل≤ 1260nm
التوهين (+ 20 ℃) @ 1310nm≤ 0.45dB / كم
التوهين (+ 20 ℃) @ 1550nm≤ 0.30 ديسيبل / كم
عبر / التخزين / درجة حرارة التشغيل-20℃~+60℃
درجة حرارة التركيب-5℃~+50℃
اسم العلامة التجاريةYRT
خارج غمد / سترةLSZH أو PVC
موصلات نوع من الكابلLC ، SC ، FC ، ST
تلميع نوع الموصلUPC ، APC
طول الكابل10mt ، 20mt ، 30mt ، 50mt ، 100mt أو حسب طلبك
ملاحظة: الكابل الأساسية استخدام الألياف طلاء الملونة من 250μm.

هيكل المنتج وتكوينه

Outer Jacket Options

• LSZH (Low Smoke Zero Halogen)

• PVC or PE available per customer request

Connector Types

• SC/UPC, SC/APC, FC, LC available

Fiber Count

• 1 core or 2 cores as standard

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)

فوائد من  Pre-Connected FTTH Drop Cable

Effortless Plug-and-Play Installation

Factory pre-terminated connectors completely eliminate on-site splicing, enabling exceptionally fast and reliable fiber connections. The compact and lightweight cable design further simplifies handling and routing, making installation straightforward even in tight spaces or congested pathways.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)

Application-Optimized Connectivity and Transmission

Engineered for versatility, the cable is available with G652D, G655, or G657A fibers to cover diverse bending and distance requirements, and supports SC, FC, or LC connectors with fully customizable lengths. Consistently low insertion loss and high return loss guarantee stable, high-performance optical transmission across every deployment scenario.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن2)

التطبيقات الهندسية  Pre-Connected FTTH Drop Cable

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)

1. Multi-Dwelling Unit (MDU) Fiber Deployments

In high-rise apartment buildings and condominiums, pre-connected drop cables are widely used to bridge the floor distribution box and individual living units. The cable, factory-terminated with SC/APC or LC connectors, is simply plugged into the riser splitter and the ONT inside the apartment. The compact, lightweight design allows easy routing through crowded cable trays and micro-ducts, while the LSZH jacket meets strict in-building fire safety codes. This eliminates the need for on-site fusion splicing in confined telecom closets, dramatically reducing per-subscriber connection time and minimizing disruption to residents.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن2)

2. Single-Family Home (SFU) Last-Mile Connections

During greenfield or overbuild FTTH rollouts in suburban neighborhoods, pre-connected drop cables connect the network access point (a pole-mounted closure or handhole near the property line) directly to the optical network terminal on or inside the home. Installers select a cable with a pre-measured length and simply unspool it, route it along the exterior wall or through buried conduit, and plug it in. With G657A bend-insensitive fiber, the cable can take tight 90-degree corners around eaves and corners without signal loss, and the factory-terminated connectors ensure consistent low insertion loss — critical for maintaining link budgets over long distribution sections.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن3)

3. Rapid Rural and Low-Density Area FTTH Deployments

In sparsely populated rural areas, where each subscriber is often far from the next, sending a skilled splicing technician to every individual drop location is prohibitively expensive and time-consuming. Pre-connected drop cables enable a “plug-and-play” installation model: a field technician with minimal fiber training can complete the final drop by simply connecting pre-terminated ends at a roadside distribution closure and at the home’s customer termination box. Customizable lengths up to hundreds of meters and outdoor-rated PE jackets allow the cable to be directly buried or strung aerially without intermediate splices, accelerating deployment and significantly lowering labor costs.

الشحن والتغليف

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)    كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن2)

تفاصيل Packaging

كل لفة تحتوي على 1-5 كم من الكابلات ، وعادة ما تكون معبأة في براميل الصلب. تتوفر حلول التغليف المخصصة عند طلب العميل.


غمد وسم

يتم تطبيق المسافة البادئة للرقائق الساخنة البيضاء على فترات 1 متر مع المعلومات التالية:

ا. اسم المورد: Guanglian (أو كما هو محدد من قبل العميل)
b. الكود القياسي بما في ذلك نوع المنتج ونوع الألياف وعدد الألياف
c. سنة الصنع (صالحة لمدة 7 سنوات)
d. طول مؤشر بالأمتار


ميناء الشحن

الموانئ المتاحة: تشينغداو ، قوانغتشو ، شنتشن


المهلة الزمنية المقدرة

Quantity (KM)Estimated Delivery Time
1–300تقريبا. 15 يوم
≥300وقت التسليم للتفاوض



ملاحظة

تفاصيل التعبئة أعلاه هي للإشارة فقط. سيتم تأكيد حجم التعبئة النهائية والوزن قبل الشحن.



مقارنة المنتج:

Pre-Connectorized FTTH vs Bow-type FTTH vs Field-Terminated Drop Cable

Feature / DimensionPre-Connectorized FTTH Drop CableStandard Flat/Bow-type FTTH Drop CableField-Terminated / Non-Preconnectorized Drop Cable
Structural FeaturesFactory‑terminated with hardened connectors (SC/APC, LC/APC); ruggedized flat/round drop cable (dielectric or armored); IP68 waterproof/dustproof sealing boot; optional pulling eye; stub end for splicing or connector interface available.Butterfly/flat “figure‑8” cross‑section with two parallel FRP/steel strength members and central fiber core; outer LSZH/PE jacket, UV resistant; self‑supporting version available with steel wire messenger; completely gel‑free/dry design; G.657 bend‑insensitive fibre support.Blunt‑ended drop cable with no factory connectors; requires field splicing (fusion) or mechanical field termination; gel‑filled or dry loose tube designs available; connector components packaged separately; G.657/G.652 fibre options.
Installation ProcessPlug‑and‑play, tool‑less connection; no field termination or fusion splicing required; quick cable gland attachment; direct connection to MST/ONT; pulling eye facilitates deployment in ducts; factory‑terminated and 100% tested.Field‑based preparation and termination required; requires stripping outer sheath, cleaning gel (if present), cleaving fibres, and installing field connectors or splicing pigtails; more labour‑intensive process; skilled labour required for termination.Field‑terminated using fusion splicing or mechanical connectors during installation; requires expensive field termination tools and splicing equipment; fusion process involves cleaning, cleaving, heating, and heat‑shrinking; slow and labour‑intensive; highly skilled labour required.
Performance ReliabilityVery high – factory‑terminated connectors ensure consistent, high‑quality, low‑loss connections (IL ≤0.3dB, RL ≥60dB); each assembly 100% factory‑tested; environmental testing per GR‑3120, GR‑326, Telcordia standards; far more reliable than field‑terminated alternatives.Moderate to high – reliability depends on field termination quality; precision of cut and connector assembly directly affects IL/RL; risk of high IL if termination is poor; consistent performance requires proper training and clean field environment.Variable – reliability depends heavily on installer skill and field conditions; high potential for insertion loss, return loss, and field failures; fusion splicing offers better reliability than mechanical connectors, but still lower than factory‑terminated assemblies; higher risk of contamination or damage in uncontrolled field environment.
Cost (Relative)Higher initial material cost (premium for factory‑termination); significantly lower labour cost and faster deployment; lower long‑term TCO in high‑labour‑cost markets due to reduced installation time and errors.Low material cost (no pre‑attached connectors); moderate labour cost for field preparation and connectorisation; overall moderate TCO.Lowest material cost (blunt cable only); highest labour cost (field splicing/connectorisation requires time and skilled labour); requires expensive field termination tools and splicing machines; higher TCO in high‑labour‑cost markets, but may be economical in low‑labour‑cost regions.
Installation SpeedFast – connects in minutes; plug‑and‑play reduces deployment time and eliminates splicing steps; high‑volume rapid rollouts achievable; service activation downtime minimised.Moderate – takes 10‑20 minutes per termination depending on field connector type; overall project timeline longer than pre‑connectorized due to labour‑intensive steps.Slow – each termination takes significant field time; requires fusion splicing or mechanical assembly; cleaning, cleaving, heating, and heat‑shrinking steps; installation speed much slower than pre‑connectorized; more susceptible to weather/environment delays.
Connector OptionsSC/APC, LC/APC, hardened SC, MPO; industry‑standard footprints; hardened connector to SC/APC (1F/2F); hardened connector to LC/APC.Typically none pre‑attached – field‑terminated with standard SC/APC or LC/APC connectors using pigtails or field‑installable connectors; no factory connector options.None pre‑attached; field‑terminated with SC/APC, LC/APC, or hardened connectors depending on termination method used; mechanical or fusion‑spliced pigtails.
All‑Dielectric (EMI Immune)Yes (dielectric cable version); armoured versions contain steel for mechanical protection but all‑dielectric option available.Yes – FRP strength members, no metal components; completely immune to EMI, no grounding required; ideal for deployment near power lines or in high‑EMI environments.Yes – same as Standard Flat/Bow‑type cable (non‑preconnectorized cable bodies).
Flame RetardancyLSZH (standard); outdoor UV‑resistant PE jacket optional; meets fire safety codes for outdoor and indoor transition spaces; low smoke, halogen‑free.PE or LSZH; PE offers excellent UV and weather resistance for long‑term outdoor exposure but not flame‑retardant; LSZH version available for fire‑rated spaces.Same as Standard Flat/Bow‑type cable (non‑preconnectorized cable bodies).
Typical ApplicationsFTTH networks (MDU, SFU); connecting multiport service terminals (MSTs) to subscriber terminals; FTTA base station connections; outdoor to indoor fibre transition; rural broadband buildouts; data centres and enterprise networks; mobile backhaul/5G.FTTH aerial (self‑supporting) drop cabling between pole and house; above‑ground building access networks; indoor/outdoor transition where pre‑connectorized is cost‑prohibitive; standard FTTH last‑metre deployments.FTTH deployments in low‑labour‑cost markets where skilled labour is available and field termination is cost‑effective; emergency repairs requiring exact cable lengths; MDU riser where exact length is unknown before installation; applications requiring field splicing to existing infrastructure.

Pre-Connected FTTH Drop Cable  دليل الاختيار

Pre-Connectorized FTTH Drop Cable – Short Installation Guide

1. Site Survey & Cable Length Verification:Confirm the distance between the MST (Multiport Service Terminal) and the subscriber ONT. Order pre‑connectorized cables with the exact length required. Avoid excessive slack.

2. Cable Routing & Pulling:Route the cable through ducts, conduits, or aerial supports. Use the integrated pulling eye or pull by the cable jacket (never pull by the connector). Maintain pulling tension ≤100 N. Minimum bending radius: 20× cable OD.

3. Connector Protection & Cleaning:Keep the factory‑installed dust cap on until final connection. Clean the connector end‑face with a dry or alcohol‑wipe cleaner before plugging in. Inspect using a fiber microscope if available.

4. Final Connection & Slack Storage:Remove the dust cap and connect directly to MST or ONT. Hand‑tighten the IP68 sealing boot. Coil any excess cable in the terminal box or on the pole using a figure‑8 pattern.

5. Acceptance Test:Check the signal level using an optical power meter. For active PON networks, verify ONT registration and link status. Typical insertion loss should be ≤0.5 dB for the whole drop assembly.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)

تنزيل كتالوج منتجات YRTFIBER

قم بتنزيل الكتالوج بسرعة
لتوفير وقتك ، يرجى تنزيل الكتالوج الخاص بنا

مصنع لقطة حقيقية

Stranding & Sheathing Line

General view of the cable core assembly zone.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن1)

GYFTY53 Manufacturing Plant Overview

A clean and well‑organized production floor.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن2)

Raw Material Storage

FRP rods, loose tubes, steel tape, and PE compounds.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن3)

Factory Warehouse & Dispatch

Ready‑to‑ship fiber cable coils awaiting delivery.

كابل إسقاط FTTH متصل مسبقًا بألياف G652D / G655 / G657A(حزمة والشحن4)

الأسئلة المتداولة والاستفسار السريع

Pre-Connected FTTH Drop Cable  FAQ

Q1: ما هو كابل إسقاط FTTH متصل مسبقًا ؟
A1: إنه كابل ألياف منتهي في المصنع مع موصلات ، جاهز لتركيب التوصيل والتشغيل.


Q2: ما هي أنواع الألياف المتاحة ؟
A2: تتوفر ألياف أحادية الوضع G652D و G655 و G657A.


Q3: هل يمكنني اختيار نوع الموصل وطوله ؟
A3: نعم ، يتم دعم SC / UPC و SC / APC و LC و FC وأطوال مخصصة.


Q4: هل هذا الكابل مناسب للاستخدام في الهواء الطلق ؟
A4: نعم ، السترة مقاومة للماء ، ومقاومة للأشعة فوق البنفسجية ، ومثبطات اللهب.


Q5: أين يمكن استخدام هذا الكابل ؟
A5: مثالي لـ FTTH والوصول إلى الميل الأخير والشبكات السكنية أو المكتبية.


إرسال الاستفسار الخاص بك

املأ النموذج أدناه وسنعاود الاتصال بك في غضون 24 ساعة.

مقالات ذات صلة

التكنولوجيات ذات الصلة

استكشاف المعرفة وراء هذا المنتج

x
إرسال استفسارك اليوم
We use cookie to improve your online experience. By continuing to browse this website, you agree to our use of cookie.

Cookies

Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
We may modify this Policy at any time, without prior notice, and changes may apply to any Personal Information we already hold about you, as well as any new Personal Information collected after the Policy is modified. If we make changes, we will notify you by revising the date at the top of this Policy. We will provide you with advanced notice if we make any material changes to how we collect, use or disclose your Personal Information that impact your rights under this Policy. If you are located in a jurisdiction other than the European Economic Area, the United Kingdom or Switzerland (collectively “European Countries”), your continued access or use of our Services after receiving the notice of changes, constitutes your acknowledgement that you accept the updated Policy. In addition, we may provide you with real time disclosures or additional information about the Personal Information handling practices of specific parts of our Services. Such notices may supplement this Policy or provide you with additional choices about how we process your Personal Information.


Cookies

Cookies are small text files stored on your device when you access most Websites on the internet or open certain emails. Among other things, Cookies allow a Website to recognize your device and remember if you've been to the Website before. Examples of information collected by Cookies include your browser type and the address of the Website from which you arrived at our Website as well as IP address and clickstream behavior (that is the pages you view and the links you click).We use the term cookie to refer to Cookies and technologies that perform a similar function to Cookies (e.g., tags, pixels, web beacons, etc.). Cookies can be read by the originating Website on each subsequent visit and by any other Website that recognizes the cookie. The Website uses Cookies in order to make the Website easier to use, to support a better user experience, including the provision of information and functionality to you, as well as to provide us with information about how the Website is used so that we can make sure it is as up to date, relevant, and error free as we can. Cookies on the Website We use Cookies to personalize your experience when you visit the Site, uniquely identify your computer for security purposes, and enable us and our third-party service providers to serve ads on our behalf across the internet.

We classify Cookies in the following categories:
 ●  Strictly Necessary Cookies
 ●  Performance Cookies
 ●  Functional Cookies
 ●  Targeting Cookies


Cookie List
A cookie is a small piece of data (text file) that a website – when visited by a user – asks your browser to store on your device in order to remember information about you, such as your language preference or login information. Those cookies are set by us and called first-party cookies. We also use third-party cookies – which are cookies from a domain different than the domain of the website you are visiting – for our advertising and marketing efforts. More specifically, we use cookies and other tracking technologies for the following purposes:

Strictly Necessary Cookies
These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. You can set your browser to block or alert you about these cookies, but some parts of the site will not then work. These cookies do not store any personally identifiable information.

Functional Cookies
These cookies enable the website to provide enhanced functionality and personalisation. They may be set by us or by third party providers whose services we have added to our pages. If you do not allow these cookies then some or all of these services may not function properly.

Performance Cookies
These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.

Targeting Cookies
These cookies may be set through our site by our advertising partners. They may be used by those companies to build a profile of your interests and show you relevant adverts on other sites. They do not store directly personal information, but are based on uniquely identifying your browser and internet device. If you do not allow these cookies, you will experience less targeted advertising.

How To Turn Off Cookies
You can choose to restrict or block Cookies through your browser settings at any time. Please note that certain Cookies may be set as soon as you visit the Website, but you can remove them using your browser settings. However, please be aware that restricting or blocking Cookies set on the Website may impact the functionality or performance of the Website or prevent you from using certain services provided through the Website. It will also affect our ability to update the Website to cater for user preferences and improve performance. Cookies within Mobile Applications

We only use Strictly Necessary Cookies on our mobile applications. These Cookies are critical to the functionality of our applications, so if you block or delete these Cookies you may not be able to use the application. These Cookies are not shared with any other application on your mobile device. We never use the Cookies from the mobile application to store personal information about you.

If you have questions or concerns regarding any information in this Privacy Policy, please contact us by email at . You can also contact us via our customer service at our Site.