Câble de chute FTTH pré-connecté avec fibres G652D / G655 / G657A
Factory pre-terminated connectors ensure fast and reliable installation.
Available with G652D, G655. or G657A fibers for various bending and distance requirements.
Supports SC/FC/LC connectors and customizable fiber lengths.
Compact, lightweight design for easy handling and routing.
Low insertion loss and high return loss for stable transmission.
What is Pre-Connected FTTH Drop Cable
Pre-Connected FTTH Drop Cable is a plug-and-play optical cable solution that pre-terminates connectors within the factory. It uses G652D, G655. or G657A fibers to meet different bending and transmission distance requirements, fundamentally eliminating on-site splicing, significantly shortening installation time, and improving the reliability of fiber-to-the-home networks. It is typically available in 1-core or 2-core specifications, supporting various connector types such as SC/APC, SC/UPC, FC, LC, and can be customized as needed. The outer sheath offers options for low smoke halogen-free (LSZH), PVC, or PE, catering to both indoor and outdoor environments. With its compact and lightweight structure, low insertion loss, and high return loss, this cable is easy to deploy and route management, ensuring stable transmission performance. It is widely used for fast fiber deployment in FTTH indoor and outdoor access, residential and small office networks, making it an ideal choice for last-mile connection and introductory installation.
Pre-Connected FTTH Drop Cable Paramètres de spécification
- Paramètres de spécification
- CARACTÉRISTIQUES OPTIQUES
Spécifications
| Article | Données |
| Longueur de coupure du câble | ≤ 1260nm |
| Atténuation (+ 20 ℃) @ 1310nm | ≤ 0,45 dB / km |
| Atténuation (+ 20 ℃) @ 1550nm | ≤ 0,30dB / km |
| Trans / Stockage / Température de fonctionnement | -20℃~+60℃ |
| Température d'installation | -5℃~+50℃ |
| Nom de la marque | YRT |
| Gaine / Veste | LSZH ou PVC |
| Connecteurs type du câble | LC, SC, FC, ST |
| Type de polissage du connecteur | UPC, APC |
| Longueur du câble | 10mt, 20mt, 30mt, 50mt, 100mt ou en tant que votre demande |
| Remarque : le noyau du câble utilise la fibre de revêtement colorée de 250 μm ; | |
Structure et composition du produit
Outer Jacket Options
• LSZH (Low Smoke Zero Halogen)
• PVC or PE available per customer request
Connector Types
• SC/UPC, SC/APC, FC, LC available
Fiber Count
• 1 core or 2 cores as standard

Avantages de Pre-Connected FTTH Drop Cable
Effortless Plug-and-Play Installation
Factory pre-terminated connectors completely eliminate on-site splicing, enabling exceptionally fast and reliable fiber connections. The compact and lightweight cable design further simplifies handling and routing, making installation straightforward even in tight spaces or congested pathways.

Application-Optimized Connectivity and Transmission
Engineered for versatility, the cable is available with G652D, G655, or G657A fibers to cover diverse bending and distance requirements, and supports SC, FC, or LC connectors with fully customizable lengths. Consistently low insertion loss and high return loss guarantee stable, high-performance optical transmission across every deployment scenario.

Applications d'ingénierie Pre-Connected FTTH Drop Cable
Expédition et emballage

Packaging Détails
Chaque rouleau contient 1 à 5 KM de câble, généralement emballé dans des fûts en acier. Des solutions d'emballage personnalisées sont disponibles sur demande du client.
Marquage de gaine
L'indentation de la feuille blanche chaude est appliquée à des intervalles de 1 mètre avec les informations suivantes :
a. Nom du fournisseur : Guanglian (ou tel que spécifié par le client)
b. Code standard comprenant le type de produit, le type de fibre et le nombre de fibres
c. Année de fabrication (valable 7 ans)
d. Indication de la longueur en mètres
Port d'expédition
Ports disponibles : Qingdao, Guangzhou, Shenzhen
Délai estimé
| Quantity (KM) | Estimated Delivery Time |
|---|---|
| 1–300 | Environ 15 jours |
| ≥300 | Délai de livraison à négocier |
Note
Les détails d'emballage ci-dessus sont à titre de référence uniquement. La taille et le poids finaux de l'emballage seront confirmés avant l'expédition.
Comparaison des produits:
Pre-Connectorized FTTH vs Bow-type FTTH vs Field-Terminated Drop Cable
| Feature / Dimension | Pre-Connectorized FTTH Drop Cable | Standard Flat/Bow-type FTTH Drop Cable | Field-Terminated / Non-Preconnectorized Drop Cable |
|---|---|---|---|
| Structural Features | Factory‑terminated with hardened connectors (SC/APC, LC/APC); ruggedized flat/round drop cable (dielectric or armored); IP68 waterproof/dustproof sealing boot; optional pulling eye; stub end for splicing or connector interface available. | Butterfly/flat “figure‑8” cross‑section with two parallel FRP/steel strength members and central fiber core; outer LSZH/PE jacket, UV resistant; self‑supporting version available with steel wire messenger; completely gel‑free/dry design; G.657 bend‑insensitive fibre support. | Blunt‑ended drop cable with no factory connectors; requires field splicing (fusion) or mechanical field termination; gel‑filled or dry loose tube designs available; connector components packaged separately; G.657/G.652 fibre options. |
| Installation Process | Plug‑and‑play, tool‑less connection; no field termination or fusion splicing required; quick cable gland attachment; direct connection to MST/ONT; pulling eye facilitates deployment in ducts; factory‑terminated and 100% tested. | Field‑based preparation and termination required; requires stripping outer sheath, cleaning gel (if present), cleaving fibres, and installing field connectors or splicing pigtails; more labour‑intensive process; skilled labour required for termination. | Field‑terminated using fusion splicing or mechanical connectors during installation; requires expensive field termination tools and splicing equipment; fusion process involves cleaning, cleaving, heating, and heat‑shrinking; slow and labour‑intensive; highly skilled labour required. |
| Performance Reliability | Very high – factory‑terminated connectors ensure consistent, high‑quality, low‑loss connections (IL ≤0.3dB, RL ≥60dB); each assembly 100% factory‑tested; environmental testing per GR‑3120, GR‑326, Telcordia standards; far more reliable than field‑terminated alternatives. | Moderate to high – reliability depends on field termination quality; precision of cut and connector assembly directly affects IL/RL; risk of high IL if termination is poor; consistent performance requires proper training and clean field environment. | Variable – reliability depends heavily on installer skill and field conditions; high potential for insertion loss, return loss, and field failures; fusion splicing offers better reliability than mechanical connectors, but still lower than factory‑terminated assemblies; higher risk of contamination or damage in uncontrolled field environment. |
| Cost (Relative) | Higher initial material cost (premium for factory‑termination); significantly lower labour cost and faster deployment; lower long‑term TCO in high‑labour‑cost markets due to reduced installation time and errors. | Low material cost (no pre‑attached connectors); moderate labour cost for field preparation and connectorisation; overall moderate TCO. | Lowest material cost (blunt cable only); highest labour cost (field splicing/connectorisation requires time and skilled labour); requires expensive field termination tools and splicing machines; higher TCO in high‑labour‑cost markets, but may be economical in low‑labour‑cost regions. |
| Installation Speed | Fast – connects in minutes; plug‑and‑play reduces deployment time and eliminates splicing steps; high‑volume rapid rollouts achievable; service activation downtime minimised. | Moderate – takes 10‑20 minutes per termination depending on field connector type; overall project timeline longer than pre‑connectorized due to labour‑intensive steps. | Slow – each termination takes significant field time; requires fusion splicing or mechanical assembly; cleaning, cleaving, heating, and heat‑shrinking steps; installation speed much slower than pre‑connectorized; more susceptible to weather/environment delays. |
| Connector Options | SC/APC, LC/APC, hardened SC, MPO; industry‑standard footprints; hardened connector to SC/APC (1F/2F); hardened connector to LC/APC. | Typically none pre‑attached – field‑terminated with standard SC/APC or LC/APC connectors using pigtails or field‑installable connectors; no factory connector options. | None pre‑attached; field‑terminated with SC/APC, LC/APC, or hardened connectors depending on termination method used; mechanical or fusion‑spliced pigtails. |
| All‑Dielectric (EMI Immune) | Yes (dielectric cable version); armoured versions contain steel for mechanical protection but all‑dielectric option available. | Yes – FRP strength members, no metal components; completely immune to EMI, no grounding required; ideal for deployment near power lines or in high‑EMI environments. | Yes – same as Standard Flat/Bow‑type cable (non‑preconnectorized cable bodies). |
| Flame Retardancy | LSZH (standard); outdoor UV‑resistant PE jacket optional; meets fire safety codes for outdoor and indoor transition spaces; low smoke, halogen‑free. | PE or LSZH; PE offers excellent UV and weather resistance for long‑term outdoor exposure but not flame‑retardant; LSZH version available for fire‑rated spaces. | Same as Standard Flat/Bow‑type cable (non‑preconnectorized cable bodies). |
| Typical Applications | FTTH networks (MDU, SFU); connecting multiport service terminals (MSTs) to subscriber terminals; FTTA base station connections; outdoor to indoor fibre transition; rural broadband buildouts; data centres and enterprise networks; mobile backhaul/5G. | FTTH aerial (self‑supporting) drop cabling between pole and house; above‑ground building access networks; indoor/outdoor transition where pre‑connectorized is cost‑prohibitive; standard FTTH last‑metre deployments. | FTTH deployments in low‑labour‑cost markets where skilled labour is available and field termination is cost‑effective; emergency repairs requiring exact cable lengths; MDU riser where exact length is unknown before installation; applications requiring field splicing to existing infrastructure. |
Pre-Connected FTTH Drop Cable Guide de sélection
For high‑volume FTTH/MDU deployments where installation speed, scalability, and long‑term reliability are critical, Pre‑Connectorized FTTH Drop Cable is the preferred choice. Its plug‑and‑play design eliminates field termination, reducing labour and installation errors, and delivering consistent low‑loss performance. Ideal for high‑labour‑cost markets or rapid rollouts, despite higher material cost.
For brownfield deployments, multi‑dwelling unit (MDU) retrofits, and applications where precise cable lengths cannot be determined before ordering, Field‑Terminated / Non‑Preconnectorized Drop Cable remains highly practical and often the only feasible choice. Field splicing allows installers to cut the cable to exact length on‑site, eliminating slack management issues. This makes it especially valuable in building risers where the exact distance to each subscriber unit cannot be accurately measured before installation.
For direct buried or underground duct FTTH installations where low material cost and simple handling are priorities, Standard Flat/Bow‑type FTTH Drop Cable (unterminated) is a cost‑effective choice when field termination is feasible and skilled labour available. Its compact flat profile and FRP strength members make it suitable for standard aerial/underground last‑metre connections, but the need for in‑field termination adds labour and potential quality variation.
For microduct pushing/blowing deployments requiring rapid installation and high reliability without skilled field termination, Pre‑Connectorized Drop Cable is the optimal choice. Some designs offer pre‑installed cable within conduit, which is easily pushed or blown into microducts. This significantly reduces on‑site labour while maintaining the reliability of factory‑terminated connections.
Pre‑Connectorized vs. Non‑Preconnectorized summary:
Lower labour cost region: Field‑terminated solutions may be more economical due to lower material cost.
Higher labour cost region: Pre‑connectorized offers faster installation and lower overall TCO.
Retrofit/building riser where length unknown: Field‑terminated (blunt cable) is practically mandatory.
New greenfield deployment where lengths known in advance: Pre‑connectorized offers fastest deployment and most consistent quality.
Pre-Connectorized FTTH Drop Cable – Short Installation Guide
1. Site Survey & Cable Length Verification:Confirm the distance between the MST (Multiport Service Terminal) and the subscriber ONT. Order pre‑connectorized cables with the exact length required. Avoid excessive slack.
2. Cable Routing & Pulling:Route the cable through ducts, conduits, or aerial supports. Use the integrated pulling eye or pull by the cable jacket (never pull by the connector). Maintain pulling tension ≤100 N. Minimum bending radius: 20× cable OD.
3. Connector Protection & Cleaning:Keep the factory‑installed dust cap on until final connection. Clean the connector end‑face with a dry or alcohol‑wipe cleaner before plugging in. Inspect using a fiber microscope if available.
4. Final Connection & Slack Storage:Remove the dust cap and connect directly to MST or ONT. Hand‑tighten the IP68 sealing boot. Coil any excess cable in the terminal box or on the pole using a figure‑8 pattern.
5. Acceptance Test:Check the signal level using an optical power meter. For active PON networks, verify ONT registration and link status. Typical insertion loss should be ≤0.5 dB for the whole drop assembly.

Télécharger le catalogue de produits YRTFIBER
Prise de vue réelle d'usine
Foire aux questions et enquête rapide
Pre-Connected FTTH Drop Cable FAQ
Q1 : Qu'est-ce qu'un câble de chute FTTH préconnecté?
A1: Il s'agit d'un câble fibre avec connecteurs, prêt pour une installation plug-and-play.
Q2 : Quels types de fibres sont disponibles?
A2: Les fibres monomodes G652D, G655 et G657A sont disponibles.
Q3 : Puis-je choisir le type et la longueur du connecteur?
A3: Oui, les longueurs SC / UPC, SC / APC, LC, FC et personnalisées sont prises en charge.
Q4 : Ce câble est-il adapté à une utilisation en extérieur?
A4: Oui, la veste est imperméable, résistante aux UV et ignifuge.
Q5 : Où ce câble peut-il être utilisé?
A5: Idéal pour le FTTH, l'accès au dernier kilomètre et les réseaux résidentiels ou de bureaux.
Envoyez votre demande
Remplissez le formulaire ci-dessous et nous vous répondrons dans les 24 heures.