GYFTY Неметаллический волоконно-оптический кабель | 2-288 сердечников | Небронированный наружный кабель G.652D / G.655
Good mechanical and temperature properties
High-strength loose casing, resistant to hydrolysis
Special casing filler plays a key role in protecting optical fibers
Anti-extrusion, good flexibility
Single fiber-reinforced plastic as a central reinforcement
Light weight, small diameter, easy installation
What is GYFTY fiber optic cable
GYFTY (loose tube, non-metallic, gel-filled) fiber optic cable is a fully dielectric cable that places 250 μm optical fibers into high-modulus plastic loose tubes filled with waterproof filler, which are then stranded around a central fiber-reinforced plastic (FRP) non-metallic strength member, and finally sheathed with PE, offering excellent mechanical and temperature properties, light weight, small diameter, and high resistance to electromagnetic interference, making it ideal for overhead and duct installations in power line areas or lightning-prone environments.
GYFTY Non-Metallic Fiber Optic Cable Параметры спецификации
- Параметры спецификации
- ОПТИЧЕСКИЕ ХАРАКТЕРИСТИКИ
оптические свойства
| G.652 | G.655 | 50 / 125μм | 62.5/125 мкм | ||
| Затухание (+ 20 ℃) | @ 850nm | ≤ 3,0 дБ / км | ≤ 3,0 дБ / км | ||
| @ 1300nm | ≤ 1,0 дБ / км | ≤ 1,0 дБ / км | |||
| @ 1310nm | ≤ 0,36 дБ / км | ≤ 0,40 дБ / км | |||
| @ 1550nm | ≤ 0,22 дБ / км | ≤ 0,23 дБ / км | |||
| Ширина полосы пропускания (класс A) | @ 850nm | ≥ 500 МГц · км | ≥ 200 МГц · км | ||
| @ 1300nm | ≥ 1000 МГц · км | ≥ 600 МГц · км | |||
| Численная апертура | 0.200 ± 0.015NA | 0,275 ± 0,015NA | |||
| Длина волны отключения кабеля | ≤ 1260нм | ≤ 1480нм | |||
| Хранение / Рабочая температура | -40℃ ~+70℃ | ||||
Технические параметры
| Модель | Количество волокон | Труба | Вес (кг / км) | Прочность на растяжение N | Давка N / 100мм | Радиус сгиба мм |
| GYFTY-2 ~ 36F | 2~36 | 6 | 88 | 600/1500 | 300/1000 | 10Д / 20Д |
| GYFTY-38 ~ 72F | 38~72 | 6 | 112 | 600/1500 | 300/1000 | 10Д / 20Д |
| GYFTY-74 ~ 96F | 74~96 | 8 | 155 | 600/1500 | 300/1000 | 10Д / 20Д |
| GYFTY-98 ~ 120F | 98~120 | 10 | 185 | 600/1500 | 300/1000 | 10Д / 20Д |
Структура и состав продукта
Outer Sheath (Outer Jacket): Made of polyethylene (PE) through extrusion molding, it protects the internal cable cores from mechanical damage, ultraviolet rays, and environmental corrosion, while providing good water resistance and insulation performance.
FBT Loose Tube: A loose tube made of high-modulus plastic (usually PBT, here referred to as FBT), which holds the optical fibers inside and is filled with waterproof fiber paste, providing a buffer space and lateral-pressure protection for the fibers.
Water-Blocking Material:A thixotropic fiber paste filled inside the loose tube that effectively prevents water from penetrating longitudinally along the tube while cushioning micro-bends in the fiber, ensuring long-term transmission stability.
FRP Strength Member: A glass fiber-reinforced plastic rod located at the center of the optical cable, serving as a non-metallic tensile element to withstand the tension during laying and usage and ensure the overall roundness and compactness of the cable.
Fiber: The medium for transmitting optical signals, usually 250μm colored optical fiber, placed inside the loose tube to achieve high-speed, large-capacity data communication.
Water-Blocking Material: Water-blocking grease or water-blocking yarn/powder filled in the gaps of the cable core (between the loose tube and the sheath), further preventing water from migrating longitudinally along the core and enhancing the overall water resistance of the optical cable.

Преимущества GYFTY Non-Metallic Fiber Optic Cable
Superior mechanical and environmental performance
Offers stable operation from -40℃ to +70℃, excellent crush resistance, and good flexibility, ensuring reliable performance under extrusion, bending, and temperature variation.

High-strength loose tube with protective filler
Features a hydrolysis‑resistant PBT loose tube and special thixotropic gel that blocks water, cushions micro‑bends, and effectively protects the optical fibers.

Single FRP central strength member (non‑metallic)
Uses a fiber‑reinforced plastic rod as the only central reinforcement, providing tensile strength while eliminating induced currents and lightning risks.

Lightweight, small diameter, easy installation
Optimized non‑metallic design reduces weight and outer diameter, lowering transport and handling costs, and simplifying duct blowing, overhead lashing, and other field installations.

Инженерные приложения GYFTY Non-Metallic Fiber Optic Cable
Доставка и упаковка


Packaging требования:
- 1: Все кабели должны быть намотаны на обработанные деревянные катушки, которые не подлежат возврату
- 2: Концы кабеля должны быть надежно закреплены на катушке и защищены waterproof термоусадочными колпачками
- 3: Каждая катушка должна включать:
- 1、 Protective plastic wrapping layer
- 2、 Reinforcing wooden slats for stability
- 3、 Minimum 1m of free cable end for testing purposes
- 4、 Standard spool length: 3000mm (±2% tolerance allowed)
Идентификация кабеля:
Верхняя куртка должна отображать:
- 1 、 Уникальная последовательная нумерация каждые 1 м (допускается отклонение ± 1%)
- 2 、 Дополнительные повторяющиеся маркировки с интервалами 1м, показывающие:
- 1、 Product code and fiber count
- 2、 Manufacturer identification
- 3、 Production date (month/year)
- 4、Total cable length
Standard упаковывая размеры:
| Length | Container | Size (L×W×H) | Net Mass | Total Mass |
|---|---|---|---|---|
| 2 км | Деревянная катушка | 90 × 75 × 90 см | 156 кг | 220 кг |
| 3 км | Деревянная катушка | 100 × 68 × 100 см | 240 кг | 280 кг |
| 4 км | Деревянная катушка | 109 × 75 × 109 см | 300 кг | 368 кг |
| 5 км | Деревянная катушка | 129 × 72 × 129 см | 400 кг | 480 кг |
Technical Ссылка:
- 1 、 Стандартный диаметр кабеля: 10.0mm
- 2 、 Максимальное расстояние пролета: 100 м
- 3 、 Свяжитесь с отделом продаж для получения полной технической спецификации
Стандарты маркировки катушки:
Постоянная маркировка (высота минимум 25-30 мм) должна появиться с обеих сторон каждой катушки:
- 1 、 Название компании и товарный знак
- 2 、 Содержащаяся длина кабеля
- 3 、 Спецификации кабеля (тип / количество волокон)
- 4 、 Ориентация обмотки
- 5 、 Измерения веса (брутто / нетто)
Примечание: Все деревянные упаковочные материалы перед использованием должны пройти надлежащую фумигационную обработку.
Сравнение продуктов:
GYFTY vs GYTA vs GYTS vs GYFTA
| Feature / Dimension | GYFTY (Non-Metallic, No Armor) | GYTA (Aluminum Tape Armor) | GYTS (Steel Tape Armor) | GYFTA (Non-Metallic + Aluminum Tape Armor) |
|---|---|---|---|---|
| Structure Type | Stranded loose tube around FRP (non-metallic) central strength member. Non-metallic construction throughout. | Stranded loose tube around metallic central strength member (steel wire). | Stranded loose tube around metallic central strength member (steel wire). | Stranded loose tube around FRP (non-metallic) central strength member. Aluminum tape armor (APL). |
| Armor / Protection | No metallic armor. Aramid yarn water-blocking layer + PE outer sheath. | Corrugated aluminum tape (APL) longitudinally applied + PE sheath. | Corrugated steel tape (PSP) longitudinally applied + PE sheath. | Corrugated aluminum tape (APL) + PE sheath. All-dielectric aside from aluminum tape. |
| Fiber Core Capacity | 2 – 144 cores (up to 288 cores in some designs) | 2 – 144 cores (up to 432 cores) | 2 – 144 cores (up to 432 cores) | 2 – 144 cores (up to 288 cores) |
| Typical Applications | Aerial, duct. High‑voltage areas, lightning‑prone regions, substations, environments requiring no grounding. | Duct, aerial (with messenger). Long‑haul backbone, metropolitan networks, wet/coastal areas (corrosion‑resistant). | Duct, aerial (with messenger), direct burial. Harsh environments requiring high crush resistance, rodent protection. | Duct, aerial. High‑voltage areas needing better moisture barrier than GYFTY, but with non‑metallic central member. |
| Engineering Pros | Fully dielectric – no grounding required, immune to EMI/lightning, safe near power lines. Lightweight, easy to install. UV‑resistant PE sheath, water‑blocking compound. | Excellent moisture/corrosion resistance (aluminum does not rust). Lighter and more flexible than steel armor. Good for long‑term duct installation. | High crush resistance and mechanical protection. Excellent for rodent/bullet protection in direct burial. Strong moisture barrier with PSP tape. | Combines dielectric central member (no induced current) with aluminum armor for moisture protection. Better corrosion resistance than steel armor. Lighter than GYTS. |
| Engineering Cons | No armor – weaker crush resistance, vulnerable to rodent attack. Not suitable for direct burial or high mechanical stress environments. | Lower crush resistance than steel armor (aluminum is softer). Not ideal for direct burial or rocky terrain. Metallic, requires grounding near power lines. | Heavier and stiffer than GYTA. Steel tape can corrode if sheath damaged. Metallic, requires grounding, may induce current near HV lines. | Aluminum armor has lower crush resistance than steel. Still requires care in rocky direct burial. Cost higher than GYFTY. |
| Cost (Relative) | Low – simple non‑armored construction, most economical for low‑core‑count non‑hazardous aerial/duct installations. | Medium – aluminum tape is cheaper than steel, but metallic construction adds moderate cost. | Medium to high – steel armor increases material and shipping costs, but good value for high‑protection needs. | Medium to high – non‑metallic member plus aluminum armor costs more than GYFTY but less than GYTS for similar protection in sensitive electrical environments. |
| Maintenance Difficulty | Low – lightweight, easy handling, no grounding required. However, lack of armor means higher risk of damage, requiring more frequent inspections. | Low – good corrosion resistance reduces long‑term issues; easier mid‑span access than steel armor. | Moderate – heavier and stiffer, harder to splice mid‑span; must inspect for rust at sheath damage points. | Low to moderate – lighter than GYTS; aluminum corrosion resistance good, but aluminum armor is softer and may dent, requiring careful handling. |
| Grounding Requirement | None – fully dielectric, no induced current. | Required – metallic components can induce current near power lines. | Required – same as GYTA. | Not required for central member, but aluminum tape is metallic and may require grounding in HV environments. |
GYFTY Non-Metallic Fiber Optic Cable Руководство по выбору
1 : Engineering selection between GYFTY, GYTA, GYTS and GYFTA:
For aerial or duct installation in high-voltage environments, GYFTY is recommended due to its all-dielectric construction, which eliminates the need for grounding and prevents induced current in lightning-prone or power-line adjacent areas. For applications requiring a dielectric cable with better moisture protection than GYFTY but without the weight of steel armor, GYFTA can be an ideal choice. For pipe-laying in wet or coastal areas, GYTA is suitable for its corrosion resistance, lighter weight, and good moisture barrier. For direct burial, rodent protection, or high mechanical stress scenarios, GYTS provides superior crush resistance but its steel armor is heavier and needs extra rust inspection at sheath damage points.
2 : Flame retardancy and UV resistance considerations:
All four cables are primarily designed for outdoor use with UV-resistant PE sheaths and water‑blocking gel for moisture protection, meeting standards like IEC 60794-1 and YD/T 901. They are not flame‑retardant, so they are not suitable for indoor riser/plenum spaces unless a specific LSZH variant (e.g., GYTZS, GYTZA) is specified.
3: Non‑metallic vs. metallic cable applications:
GYFTY and GYFTA offer non‑metallic or partially non‑metallic constructions that reduce electrical risks when installed near live power lines. This makes them suitable for high‑voltage corridors, telecommunication towers, and wind farms where electromagnetic interference is a concern. GYTA and GYTS, with metallic central strength members, are cost‑effective for general outdoor backbone networks but require proper grounding and are not recommended directly on HV transmission towers.
GYFTY Cable Installation Instructions (Short)
Minimum bending radius: Dynamic (during pulling): 20× cable diameter; Static (after installation): 10× cable diameter.
Maximum tensile load: Long‑term: ≤600 N; Short‑term: ≤1500 N. Do not exceed to avoid fiber strain.
Cable pulling: Use a swivel pulling grip to prevent twisting. For duct installation, apply lubricant and avoid sharp edges.
Aerial installation: Suitable for lashed or duct‑mounted aerial use. Maintain proper sag and clearance from power lines.
Storage & handling: Keep cable ends sealed to prevent moisture ingress. Do not step on or crush the cable.
Temperature range: Installation: -10℃ to +60℃; Operation: -40℃ to +70℃.

Скачать каталог продукции YRTFIBER
Фабрика Real Shot
Часто задаваемые вопросы и быстрый запрос
GYFTY Non-Metallic Fiber Optic Cable FAQ
1. Что делает GYFTY отличается от бронированных кабелей, таких как GYTS или GYTA?
GYFTY - это non-metallic, небронированный оптоволоконный кабель, в котором используется арамидная пряжа для прочности на растяжение вместо стальной или алюминиевой брони. Это делает его lightweight, диэлектрическим и устойчивым к электромагнитным помехам (EMI) - идеальным рядом с линиями электропередач или в районах с электрическим шумом.
2. Подходит ли этот кабель для воздушной или воздуховодной установки?
Да. GYFTY обычно используется в overhead воздушных развертываниях или в установках duct, где металлические элементы не допускаются. Не рекомендуется для прямого захоронения без трубопровода из-за отсутствия брони.
3. Какова емкость сердечника волокна этого кабеля?
Кабель GYFTY поддерживает от 2 до 288 ядер одномодовых волокон G.652D или G.655, обеспечивая гибкость развертывания магистрали, сети метро или сети доступа.
4. Улучшает ли полностью диэлектрическая конструкция безопасность или производительность?
Абсолютно. all-dielectric конструкция гарантирует, что кабель non-conductive, что значительно повышает безопасность в high-voltage или подверженных молнии районах. Это также исключает риск заземляющих контуров или электрической проводимости через кабель.
5. Каковы идеальные варианты использования кабеля GYFTY?
GYFTY лучше всего использовать в:
High-voltage коридоры или линии электропередач
Телекоммуникационные сети
EMI-sensitive среды (например, подстанции)
FTTx и долгосрочные развертывания без металла
Отправьте запрос