Cabo de fibra blindada retardador de chama GYXTZW | 2 tamanhos 24 Cores | Uni-Tube G.652D / G.655 para uso interno-externo
1:Good mechanical properties, good high temperature resistance
2:Loose casing with high strength and resistance to hydrolysis
3:Special casing filler plays a key role in protecting optical fibers
4:Anti-extrusion, good flexibility
5:PSP enhanced moisture resistance
6:Two parallel wires ensure tensile strength
7:Small diameter, light weight, easy installation
8:Special sheath material, good flame retardancy
What is GYXTZW optical cable
GYXTZW optical cable is an outdoor armored optical cable that adopts a central tube structure, filled with waterproof grease, longitudinally wrapped with plastic-coated steel tape (PSP) and embedded with parallel steel wires as reinforcement, while using low-smoke, halogen-free flame-retardant (LSZH) material for the outer sheath. It combines excellent resistance to lateral pressure and tensile performance with flame-retardant, low-smoke, and halogen-free characteristics, and is widely used in subways, tunnels, chemical plants, and other scenarios with high fire safety requirements.
GYXTZW Armored Fiber Cable Parâmetros de especificação
- Parâmetros de especificação
- CARACTERÍSTICAS ÓPTICAS
Propriedades ópticas
| G.652 | G.655 | 50/125μm | 62.5/125μm | |
|---|---|---|---|---|
| Atenuação (+ 20ºC) | ≤ 3,0 dB / km @ 850nm | ≤ 3,0 dB / km @ 850nm | ||
| ≤ 1,0 dB / km @ 1300nm | ≤ 1,0 dB / km @ 1300nm | |||
| ≤ 0,36 dB / km @ 1310nm | ≤ 0,40 dB / km @ 1310nm | |||
| ≤ 0,22 dB / km @ 1550nm | ≤ 0,23 dB / km @ 1550nm | |||
| Largura de banda (Classe A) | ≥ 500 MHz · km @ 850nm | ≥ 200 MHz · km @ 850nm | ||
| ≥ 1000 MHz · km @ 1300nm | ≥ 600 MHz · km @ 1300nm | |||
| Abertura numérica | 0,200 ± 0,015NA | 0,275 ± 0,015NA | ||
| Comprimento de onda de corte do cabo | ≤ 1260nm | ≤ 1480nm | ||
| Temperatura de armazenamento / operação | -40oC ~ + 70oC | |||
ParâmetrosTechnical
| Modelo | Contagem de fibras | Diâmetro exterior (mm) | Peso (kg / km) | Resistência à tração | A paixão súbita | Raio De Dobra |
| GYXTZW-2 ~ 12 | 2~12 | 9.2 | 152 | 600/1500 | 300/1000 | 10D / 20D |
| GYXTZW-14 ~ 24 | 14~24 | 12.2 | 195 | 600/1500 | 1000/3000 | 10D / 20D |
| GYXTZW-2 ~ 12 | 2~12 | 10.8 | 172 | 1000/3000 | 1000/3000 | 10D / 20D |
| GYXTZW-14 ~ 24 | 14~24 | 12.2 | 215 | 1000/3000 | 1000/3000 | 10D / 20D |
Estrutura e Composição do Produto
Optical Fiber (250μm, e.g., G652D or G655)
Waterproof filler (thixotropic water-blocking compound inside the loose tube)
High modulus plastic loose tube (PBT, containing the optical fibers and waterproof filler)
Metal strength member (two parallel steel wires placed on both sides of the steel strip)
Water blocking tape (added between the PSP and the loose tube to ensure compactness and waterproofing)
Coated steel tape (PSP) (longitudinally wrapped around the loose tube for moisture resistance and anti-extrusion)
Flame-retardant outer sheath (LSZH material, providing low smoke, halogen-free, and flame-retardant properties)

Benefícios de GYXTZW Armored Fiber Cable
Excellent mechanical performance and high-temperature resistance:
resistant to extrusion, flexible, and capable of withstanding high temperatures.

High-strength, hydrolysis-resistant loose tubes and special filling grease:
the loose tubes are high-strength and hydrolysis-resistant, and the special filling grease inside the tubes effectively protects the optical fibers.

Multiple protective structures enhance tensile and moisture resistance:
PSP coated steel tape improves moisture resistance, while parallel steel wires on both sides ensure tensile strength.

Lightweight and compact, flame-retardant and easy to install:
small outer diameter, light weight, easy to install, and uses special flame-retardant jacket material with excellent fire performance.

Aplicações de Engenharia GYXTZW Armored Fiber Cable
Envio & Embalagem


Packaging Requisitos:
- 1: Todos os cabos devem ser enrolados em carretéis de madeira tratados que não sejam retornáveis
- 2: As extremidades do cabo devem ser firmemente presas ao carretel e protegidas com waterproof tampas retráteis
- 3: Cada carretel deve incluir:
- 1、 Protective plastic wrapping layer
- 2、 Reinforcing wooden slats for stability
- 3、 Minimum 1m of free cable end for testing purposes
- 4、 Standard spool length: 3000mm (±2% tolerance allowed)
Identificação do cabo:
O revestimento exterior deve apresentar:
- 1 、 Numeração sequencial única a cada 1m (variação de ± 1% permitida)
- 2 、 Marcações repetidas adicionais em intervalos de 1m mostrando:
- 1、 Product code and fiber count
- 2、 Manufacturer identification
- 3、 Production date (month/year)
- 4、Total cable length
Standard Dimensões da Embalagem:
| Length | Container | Size (L×W×H) | Net Mass | Total Mass |
|---|---|---|---|---|
| 2 km | Carretel de madeira | 90 × 75 × 90 cm | 156Kg | 220Kg |
| 3 km | Carretel de madeira | 100 × 68 × 100 cm | 240Kg | 280Kg |
| 4 km | Carretel de madeira | 109 × 75 × 109 cm | 300Kg | 368Kg |
| 5 km | Carretel de madeira | 129 × 72 × 129 cm | 400Kg | 480Kg |
Technical Referência:
- 1 、 Diâmetro padrão do cabo: 10,0 mm
- 2 、 Distância máxima do vão: 100m
- 3 、 Entre em contato com a equipe de vendas para especificações técnicas completas
Padrões de marcação de spool:
As marcações permanentes (altura mínima de 25-30 mm) devem aparecer em ambos os lados de cada carretel:
- 1 、 Nome da empresa e marca comercial
- 2 、 Comprimento do cabo contido
- 3 、 Especificações do cabo (tipo / contagem de fibra)
- 4 、 Orientação do enrolamento
- 5 、 Medidas de peso (bruto / líquido)
Nota: Todos os materiais de embalagem de madeira devem ser submetidos a um tratamento de fumigação adequado antes da utilização.
Comparação de produtos:
GYXTZW vs GYXTW vs GYXTY vs GYTS
| Feature / Dimension | GYXTZW (Central Tube, Steel Tape Armor, LSZH) | GYXTW (Central Tube, Steel Tape Armor) | GYXTY (Central Tube, Non-Armored) | GYTS (Stranded, Steel Tape Armor) |
|---|---|---|---|---|
| Structure Type | Central loose tube, steel tape armor (PSP), two parallel steel wires, LSZH outer sheath. | Central loose tube, steel tape armor (PSP), two parallel steel wires, PE outer sheath. | Central loose tube, two parallel steel wires, PE outer sheath. No steel tape armor. | Stranded loose tubes around central metal strength member, steel tape armor (PSP), PE outer sheath. |
| Armor / Protection | Steel tape armor (double-sided coated) – provides crush resistance, rodent protection, bullet resistance. | Steel tape armor (double-sided coated) – provides crush resistance, rodent protection, bullet resistance. | No steel tape armor – only two parallel steel wires as strength members. Minimal mechanical protection. | Steel tape armor (corrugated PSP) – excellent crush resistance, rodent protection, bullet resistance. |
| Outer Sheath | LSZH (Low Smoke Zero Halogen) – flame-retardant, low smoke, halogen-free, UV resistant. | PE (Polyethylene) – UV resistant, weather resistant, but not flame-retardant (burns with smoke). | PE (Polyethylene) – UV resistant, weather resistant, not flame-retardant. | PE (Polyethylene) – UV resistant, weather resistant, not flame-retardant. |
| Fiber Core Capacity | 2 – 24 cores (typical), up to 48 cores in some designs. | 2 – 144 cores. | 2 – 24 cores (typical). | 2 – 288 cores (up to 432 cores in some designs). |
| Typical Applications | Aerial (with messenger), duct, direct burial. Suitable for fire-sensitive areas: tunnels, subways, power plants, chemical plants, nuclear facilities, high-rise building entry sections. | Aerial (with messenger), duct, direct burial. General outdoor access networks, FTTH, low-core-count links. | Aerial (with messenger), duct. Low-cost outdoor access networks, low mechanical stress environments. | Aerial (with messenger), duct, direct burial. Core networks, trunk lines, long-haul backbone, harsh environments requiring high crush resistance. |
| Engineering Pros | ① LSZH sheath – low smoke, halogen-free, self-extinguishing, safe for indoor/confined spaces; ② Steel tape provides excellent crush and rodent resistance; ③ Small diameter, light weight, easy handling; ④ Full-section water blocking – good moisture protection; ⑤ Suitable for both outdoor and indoor fire-rated environments. | ① Steel tape provides good crush and rodent resistance; ② Compact, small diameter, light weight; ③ Cost-effective for low core counts; ④ Full-section water blocking. | ① Lowest cost among central tube types; ② Lightweight and small diameter, easy to install; ③ PE sheath provides good UV resistance. | ① Stranded design supports very high core counts; ② Superior mechanical strength – excellent crush, tensile, and impact resistance; ③ Good moisture barrier; ④ Suitable for long-haul backbone networks. |
| Engineering Cons | ① Limited core count (≤24 cores typical); ② LSZH sheath has slightly lower UV resistance than PE for long-term outdoor exposure; ③ Higher cost than GYXTW and GYXTY due to LSZH material. | ① Not flame-retardant – cannot be used in fire-sensitive areas; ② Limited core count compared to stranded designs; ③ PE sheath not suitable for indoor/confined spaces. | ① No steel tape armor – vulnerable to rodent attack and side pressure; ② Not suitable for direct burial or harsh mechanical environments; ③ Poor crush resistance. | ① Larger diameter and heavier – harder to handle in congested ducts; ② Higher material and shipping cost; ③ Not flame-retardant; ④ More complex mid-span maintenance. |
| Flame Retardancy | LSZH – flame-retardant, low smoke, halogen-free. Suitable for tunnels, subways, high-rise entry sections (≥500m per segment). | None – PE sheath burns with smoke. Not suitable for indoor or fire-sensitive spaces. | None – same as GYXTW. | None – same as GYXTW. Flame-retardant variant available as GYTZS (LSZH). |
| Cost (Relative) | Medium to high – LSZH material and steel tape armor increase cost, but provides fire safety and mechanical protection. | Low to medium – cost-effective for low-core-count outdoor access applications. | Low – most economical option, but least protection. | Medium to high – stranded design with high core count capability increases cost. |
| Maintenance Difficulty | Low – LSZH sheath resists chemical degradation and UV; steel armor reduces fault rate; no grounding required. | Low – simple structure, easy to splice and maintain. Steel armor reduces damage risk. | Low – very easy to handle and maintain, but higher risk of damage due to lack of armor, requiring more frequent inspections. | Moderate – heavier and stiffer, harder to access mid-span; must inspect steel tape for corrosion at sheath damage points. |
GYXTZW Armored Fiber Cable Guia de Seleção
Fire-retardant cable engineering selection between GYXTZW and GYXTW/GYXTY/GYTS:
GYXTZW features steel tape armor combined with an LSZH (Low Smoke Zero Halogen) outer sheath, providing both mechanical protection and flame retardancy. It is specifically designed for outdoor installation scenarios that also require fire safety, such as cable entry sections into buildings, tunnels, subways, power plants, chemical plants, and other confined spaces where low smoke and halogen-free properties are mandatory. GYXTW, GYXTY, and GYTS all use PE sheaths which are UV-resistant and suitable for long-term outdoor exposure, but they are not flame-retardant and should never be used indoors or in fire-sensitive areas.
Fire safety and entry section requirements:
For core network entry sections (typically ≥500 meters per segment) into equipment rooms, central offices, high-rise buildings, tunnels, and other fire-rated spaces, GYXTZW with LSZH sheath is the mandatory choice. The LSZH material produces minimal smoke and no toxic halogen gases when burned, ensuring personnel safety and equipment protection in confined spaces. Standard GYXTW, GYXTY, and GYTS with PE sheaths are strictly for outdoor use only – they will burn and produce dense smoke if exposed to fire, failing building code requirements for indoor/plenum areas.
Non-flame-retardant cable applications:
GYXTW is a classic "central tube armored outdoor cable" – its PE sheath provides excellent UV resistance and long-term outdoor reliability, with steel tape armor offering good crush and rodent protection. However, it cannot be used in fire-sensitive spaces. GYXTY is the most economical option for low-core-count aerial or duct installations where mechanical stress is minimal and fire safety is not a concern – its lack of steel tape armor makes it unsuitable for direct burial or rodent-prone areas. GYTS, with its stranded loose tube design, supports much higher fiber counts (up to 288 cores or more) and offers superior mechanical strength for trunk lines and long-haul backbone networks, but it also lacks flame retardancy. For applications requiring both high mechanical strength and flame retardancy, a GYTZS (stranded, steel tape armor, LSZH) variant would be the appropriate choice.
GYXTZW Optical Cable – Brief Installation Instructions
Cable Handling – Avoid twisting or crushing. Do not exceed the rated tensile load (typically 600N short term, 300N long term).
Bending Radius – Maintain min. bending radius of 10× cable OD during installation, 20× during pulling.
Pulling – Use a pulling grip or friction-type pulling eye attached to the strength members (parallel steel wires + PSP tape).
Stripping – Remove the LSZH sheath and PSP tape carefully. Do not nick the loose tube or fibers.
Grounding – The steel wires and PSP are metallic; ground them properly at one end if required.
Flame Retardant Note – The LSZH sheath provides low smoke & halogen-free protection; avoid excessive heat during termination.
Installation Types – Suitable for aerial, duct, or direct burial (with extra protection if needed).

Baixar Catálogo de Produtos YRTFIBER
Tiro Real De Fábrica
Perguntas mais frequentes e consulta rápida
GYXTZW Armored Fiber Cable FAQ
1. Qual é o principal caso de uso do cabo de fibra retardador de chama GYXTZW?
O GYXTZW é ideal para indoor-outdoor cenários híbridos como building-to-building, substations ou túneis , onde a conformidade com a segurança contra incêndio e a proteção mecânica básica são essenciais.
2. O que torna o GYXTZW diferente dos cabos GYXTW ou GYXTY padrão?
Ao contrário do GYXTW ou GYXTY, o GYXTZW usa uma bainha externa retardadora de chamas que atende aos padrões de proteção contra incêndio ( IEC 60332, etc.), tornando-o adequado para uso em fire-regulated ambientes. Ele também possui armadura de fita de aço para maior resistência ao esmagamento.
3. Qual é a capacidade e estrutura da fibra?
O cabo suporta 2 a 24 núcleos de fibra de modo único G.652D ou G.655 em um uni-tube central cheio de gel bloqueador de água. Dois fios de aço paralelos fornecem resistência à tração, enquanto a fita de aço adiciona proteção.
4. GYXTZW é adequado para enterro direto?
Não é recomendado para sepultamento direto sem conduíte, devido à contagem limitada de núcleos e estrutura mais fina. É melhor usado em dutos, risers, bandejas ou tubulações de proteção, especialmente onde a segurança contra incêndio é uma preocupação.
5. Quais ambientes se beneficiam mais deste cabo?
GYXTZW é perfeito para:
Substations e edifícios de utilidade pública
Indoor-to-outdoor transições de fibra
Túneis de metrô e eixos de cabos
Commercial campi que exigem cabo de chama
Envie sua pergunta