288-Core GYTS Cable for a Long-Haul Outdoor Route in Cameroon: Spec Response and Test Record

2026-10-20

The customer's specification sheet is just one page, with 14 lines of parameters. It has two places where the clauses conflict with each other, and four things it doesn't mention at all—two of which directly affect how many units can be loaded per container and the delivery lead time.


What follows is not a claim that we met every requirement. It is a record of how each of those points was handled, including one sheath decision we got wrong in the first quotation and changed.

 

The following are the requirements for the client's project:

Type : Monomode G.652.D

Diamètre du cœur : 8.6 - 9.2 µm

Diamètre de la gaine : 125 µm ± 1 µm

Diamètre du revêtement primaire : 245 ± 10 µm

Atténuation maximale :

≤ 0.35 dB/km à 1310 nm

≤ 0.22 dB/km à 1550 nm

Bande de transmission : 1260 nm - 1625 nm

Dispersion chromatique : ≤ 3.5 ps/(nm·km) à 1310 nm ; ≤ 18 ps/(nm·km) à 1550 nm

PMD (Polarization Mode Dispersion) : ≤ 0.2 ps/√km

Nombre total de fibres : 144 et 288 brins

Structure : Tube libre (Loose tube) ou structure centrale tubée (Central Tube) selon l'usage

Nombre de tubes : 12 tubes × 12 fibres chacun et 24 tubes × 12 fibres chacun

Matériau du tube : PBT

Remplissage : Gel hydrofuge ou équivalent pour protection contre l'humidité

élément de renfort : FRP ou acier galvanisé

Gaine intérieure : PE noire anti-UV

Gaine extérieure : PEHD anti-rongeurs et résistante aux UV

Résistance à l'écrasement : ≥ 2000 N/10 cm

Résistance à la traction : ≥ 1500 N

Rayon de courbure : ≥ 20 × D (installation), ≥ 10 × D (en service)

Température de fonctionnement : -40 °C à +70 °C

Longueur touret : 4000 ml

Marquage : Identification métrique tous les 1 mètre, XXXX - type de câble - année de fabrication - Métrique - numéro de lot

Exemple : XXXXX-G652D-2025-1200ml-XXX

Les câbles et fibres optiques doivent être conformes aux normes suivantes :

ITU-T G.652.D

IEC 60793-1. IEC 60794-1

ISO/IEC 11801

EN 50173

RoHS et CE

 

288-Core GYTS Cable for a Long-Haul Outdoor Route in Cameroon: Spec Response and Test Record(Paquet et expédition1)


Project passport (Simplified version)

 

1. What the customer asked, and what we answered


The left column quotes the French original so the customer can check it clause by clause. ⚠️ marks a point needing clarification, 🔧 a value we tightened on our own initiative, 📌 something we added.

 

A note on ml. The customer's 4000 ml does not mean millilitres — it is mètre linéaire, linear metres. The abbreviation appears twice in the original, with two different meanings: 4000 ml in the drum-length clause is the full drum length, while 1200 ml in the marking example is the metre mark at the 1.200-metre point, not a drum length. Machine translation renders both as "millilitres", and that misreading is common enough that we wrote both meanings into our technical response — otherwise it becomes an argument at acceptance.

 

2. The designation says gyts. The construction clause allows central tube.


Structure : Tube libre ou structure centrale tubée selon l'usage. The customer specifies GYTS by name in the type field, then permits a central-tube construction in the structure field.

Both cannot be true. GYTS is defined in the YD/T 901 family as stranded loose tube + corrugated steel tape armour + PE outer sheath. Central tube is a different designation altogether (GYXTW, GYXTS and similar), with different mechanics, different bend behaviour, and no compatibility of type code.

We quoted GYTS and raised the conflict as a separate line item, asking the customer to confirm whether the type code or the construction clause takes precedence. We did not make that call for them — a wrong type code on the drum is a customs problem and an acceptance problem at the same time.

This is the only place in the whole specification where we asked the customer to change their own document.

 

3. Why 288F is 24 × 12 — and how that reaches the container count


The customer gave two fibre counts, 144F and 288F, and only two tube arrangements, 12×12 and 24×12. It looks like a stranding choice. It ends up as a logistics number.

The 144F drum is also 4.000 m, at roughly 780 kg, which gives 32 drums per container,In reality, it can only hold about 20 to 23 disks. — about 81-93 km.

This is the part of the project that is easiest to miss. The tender is written in kilometres; the shipment is priced in containers. Within one project, 144F and 288F do not have the same freight cost per kilometre. We put that into the quotation notes, which is more useful than explaining it after the cable reaches port.

On fibres per tube: at the same 288F, putting 24 fibres in each tube means thicker tube walls and a larger tube OD, so the stranded cable gets bigger and the drum gets heavier. At a fixed fibre count, tube count and fibres-per-tube trade off against each other — fewer tubes is not automatically better. 24×12 is where cable diameter and bend performance balance for this project, and it is what we quoted.

 

4. Four things the specification does not say


None of these four appear in the customer's document. We filled them in the technical response and asked for confirmation rather than waiting for an addendum — two of them change the delivery schedule.


1. Tensile is given as a single number. The original says ≥ 1500 N. It does not separate short-term from long-term, and it does not state the fibre strain permitted during loading. Those two numbers determine the strength-member cross-section and the sheath thickness, so "quote 1.500 N and move on" is not an option. We answered 1.500 N short-term / 600 N long-term, with a fibre strain limit of 0.15% under load.

 

2. "Moisture protection" has no pass criterion. The original says Gel hydrofuge ou équivalent and stops there — no test method, no acceptance limit. Testing to IEC 60794-1-22-F5 (1 m water column, 3 m sample, 24 h, no leakage) is industry practice, but industry practice is not a contract clause, and the customer can table a different method at acceptance. So we wrote the method into the response.

 

3. Drum specification is not stated — and this one blocks container loading. A 4.000 m 288F cable needs a large barrel. Too small a barrel and the cable sits on the drum at a bend tighter than the ≥20 × D installation radius the same document requires; a large barrel increases the outside diameter of the whole drum, which changes how many fit in a 40HQ. Drum specification and container count are one problem, not two.

 

4. Acceptance method is not stated. Factory acceptance, sampling on arrival, or third-party witness — three different scopes of testing and three different lead times. We quoted factory acceptance + sampling on arrival; third-party witness adds 7 working days.

5. A 110 K temperature window, and the compound it forces

 

The requirement is -40 °C à +70 °C. That is a 110 K span.


Extreme low temperature in Cameroon does not reach −40 °C. The figure most likely comes from the European standards template behind the document — the same page cites EN 50173 and ISO/IEC 11801. both European cabling standards. We did not argue the point. Meeting it costs a limited amount, so we met it. But we put the cost into the technical response so the customer knows what they are paying for.


The cost lands on the filling compound.


A 24-tube core has a lot of void. Conventional compound thickens noticeably at low temperature, the relative movement between tubes and sheath is restricted during a −40 °C bend, and that shows up directly as low-temperature excess attenuation. So this project uses a low-temperature compound, tested to IEC 60794-1-22-F1 over two cycles from −40 to +70 °C, with excess attenuation ≤ 0.05 dB/km.


The other side of that trade is drip. Soften the compound and the margin at +70 °C falls. We ran a compound-flow test on the same samples; result excellent.

Low-temperature flexibility and high-temperature non-drip are opposing requirements. You find a window; you do not take both extremes. That sentence went into the technical note to the customer, and it is also why we do not simply write "fully compliant from −40 to +70 °C".

 

6. The steel tape already stops rodents. What is the repellent for?


GYTS has double corrugated steel tape armour. That is a physical barrier — rodents do not chew through it. It is why the customer named GYTS in the first place, and it is the core value of this construction over unarmoured duct cable.

The customer then added anti-rongeurs to the outer sheath. The two are not redundant, but their priority is very different:

The steel tape carries almost all of the protection. That comes from the construction and does not decay with time.

The chemical repellent only matters in three places: the tape overlap, areas where the sheath is scored during installation, and the transition at each cable end after stripping.

So the additive is worth having, but not at maximum concentration — raise the loading and sheath tensile strength and heat-ageing life fall. That trade does not pay.

The actual construction: modified HDPE base + repellent system, outer sheath nominal 2.0mm.

One more thing we told the customer without being asked: the repellent is slow-release and decays with time and UV exposure. Over a 25-year service life, the steel tape is what still works. That is in the technical proposal document, not just in a sales conversation.

 

7. The first version — which we replaced ourselves


Our first quotation followed the specification exactly: fully imported additive system in the outer sheath. The safest position, requiring no explanation of any deviation.

Two problems. It priced 5-10% above the second version, and the imported additive carried a 1-2-week lead time against a required delivery ,The second problem mattered more than the first — price is negotiable, a delivery date is not.

So we ran a comparison: same HDPE base, two formulations, heat-aged together at 100°C for 168 h, then measured active-ingredient retention and repellent performance. Result:  domestic system retained ≥90%, difference within 3%.

On that basis we moved to the domestic system and spent the saving on 0.2 mm of extra outer sheath thickness.

The logic: trade chemical margin for structural margin. Chemical systems decay; thickness does not. Over 25 years, 0.x mm of extra sheath holds its value better than a higher additive loading.

We should also state what that decision cost. The thicker sheath adds roughly 10-12 kg/km, about 40-45 kg per 288F drum, and 20-23 the number of drums per 40HQ. That is a cost created by our own choice, not by the customer's requirement.

 

8. What was tested after sampling


The two items marked * — impact and repeated bending — are type tests. They were not repeated on this sample; the figures reference historical data from the same 288F construction platform. Everything else was measured on these samples.

Why there is no photograph of a test report here: the full records, per-drum OTDR traces and attenuation data all exist, but the reports carry the customer's name and the route location. Ask for them by project number and we will send them. This is as far as a public page can go.

 

9. Delivery:


Shipping documents (buyers tend to care about this more than about photographs — it decides whether customs and acceptance clear in one pass):

Mill Test Certificate, per batch

Per-drum OTDR trace, bidirectional, 1310 / 1550 nm

Drum number — length — attenuation cross-reference

Packing list with gross weight, net weight and outside diameter per drum

RoHS declaration · CE Declaration of Conformity

Lifting instructions: drum centre of gravity, lifting points, no laying on its side

One note on the third item: the final metre mark on each drum, the drum number and the OTDR trace must agree. This is the first thing a receiving inspector checks — a mismatch between the metre mark and the trace at 3.000 m invalidates the whole drum. We cross-check all three per drum before sealing.

 

10. What this page does not tell you


Customer name, route alignment and contract value are withheld at the customer's request. Not by our preference.

Items marked 【reference】 are taken from fibre datasheets and structural calculation, not from cabled measurements. Cabling changes them slightly through stranding and sheath compression; shipping OTDR governs.

The repellent data is in-house accelerated ageing only, with no third-party certification. If you need a third-party report, give us four weeks' notice and we will arrange it.

Drum weights are calculated from the construction. Final figures follow the process card, within 【TBD】%.

We have no other disclosable projects in Cameroon, so we cannot offer you a local reference. What we can offer is the parameters and records in this file.

 

11. Timeline


12. Related technical pages


GYTS outdoor cable — full type list and parameter table

Direct-buried cable selection — armour and sheath choice for burial

Duct cable selection — air-blown versus pull-through

Armoured cable selection — steel tape vs steel wire vs double armour

Aerial cable selection — the same construction overhead

 

13. Three questions actually asked on this project


Q: Can 288F be built as 12 tubes × 24 fibres? A: Technically yes, but 24 fibres per tube means a larger tube OD, which increases stranded cable diameter and drum weight and reduces drums per container. The specification only offered 12×12 and 24×12; we quoted 24×12.

 

Q: Can the 4.000 m drum be changed to 2.000 m? A: Yes, and it halves drum weight, which makes lifting easier. Two costs: the splice count doubles, and on a long route every splice is a point of attenuation and failure; and the drum count doubles, complicating container loading and on-site drum handling. Unless the site road or lifting equipment rules it out, we do not recommend it.

 

Q: Is 1.500 N enough tensile for 288F? A: As a short-term figure it is adequate. But the specification gives no long-term value and no permitted fibre strain. We answered 1.500 N short-term / 600 N long-term and stated the strain limit under load — those two numbers say far more about whether the cable survives pulling than the single 1.500 N does.

 

Technical parameters reviewed by Anna, Engineering (Anna is an industry expert with 15 years of technical experience in the fiber optic cable industry, having served more than a thousand fiber optic cable projects around the world over the past 15 years.). For questions on parameters, processes or alternatives, contact email : [email protected] / WhatsApp: +8615099905597.

We use cookie to improve your online experience. By continuing to browse this website, you agree to our use of cookie.

Cookies

Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
We may modify this Policy at any time, without prior notice, and changes may apply to any Personal Information we already hold about you, as well as any new Personal Information collected after the Policy is modified. If we make changes, we will notify you by revising the date at the top of this Policy. We will provide you with advanced notice if we make any material changes to how we collect, use or disclose your Personal Information that impact your rights under this Policy. If you are located in a jurisdiction other than the European Economic Area, the United Kingdom or Switzerland (collectively “European Countries”), your continued access or use of our Services after receiving the notice of changes, constitutes your acknowledgement that you accept the updated Policy. In addition, we may provide you with real time disclosures or additional information about the Personal Information handling practices of specific parts of our Services. Such notices may supplement this Policy or provide you with additional choices about how we process your Personal Information.


Cookies

Cookies are small text files stored on your device when you access most Websites on the internet or open certain emails. Among other things, Cookies allow a Website to recognize your device and remember if you've been to the Website before. Examples of information collected by Cookies include your browser type and the address of the Website from which you arrived at our Website as well as IP address and clickstream behavior (that is the pages you view and the links you click).We use the term cookie to refer to Cookies and technologies that perform a similar function to Cookies (e.g., tags, pixels, web beacons, etc.). Cookies can be read by the originating Website on each subsequent visit and by any other Website that recognizes the cookie. The Website uses Cookies in order to make the Website easier to use, to support a better user experience, including the provision of information and functionality to you, as well as to provide us with information about how the Website is used so that we can make sure it is as up to date, relevant, and error free as we can. Cookies on the Website We use Cookies to personalize your experience when you visit the Site, uniquely identify your computer for security purposes, and enable us and our third-party service providers to serve ads on our behalf across the internet.

We classify Cookies in the following categories:
 ●  Strictly Necessary Cookies
 ●  Performance Cookies
 ●  Functional Cookies
 ●  Targeting Cookies


Cookie List
A cookie is a small piece of data (text file) that a website – when visited by a user – asks your browser to store on your device in order to remember information about you, such as your language preference or login information. Those cookies are set by us and called first-party cookies. We also use third-party cookies – which are cookies from a domain different than the domain of the website you are visiting – for our advertising and marketing efforts. More specifically, we use cookies and other tracking technologies for the following purposes:

Strictly Necessary Cookies
These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. You can set your browser to block or alert you about these cookies, but some parts of the site will not then work. These cookies do not store any personally identifiable information.

Functional Cookies
These cookies enable the website to provide enhanced functionality and personalisation. They may be set by us or by third party providers whose services we have added to our pages. If you do not allow these cookies then some or all of these services may not function properly.

Performance Cookies
These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.

Targeting Cookies
These cookies may be set through our site by our advertising partners. They may be used by those companies to build a profile of your interests and show you relevant adverts on other sites. They do not store directly personal information, but are based on uniquely identifying your browser and internet device. If you do not allow these cookies, you will experience less targeted advertising.

How To Turn Off Cookies
You can choose to restrict or block Cookies through your browser settings at any time. Please note that certain Cookies may be set as soon as you visit the Website, but you can remove them using your browser settings. However, please be aware that restricting or blocking Cookies set on the Website may impact the functionality or performance of the Website or prevent you from using certain services provided through the Website. It will also affect our ability to update the Website to cater for user preferences and improve performance. Cookies within Mobile Applications

We only use Strictly Necessary Cookies on our mobile applications. These Cookies are critical to the functionality of our applications, so if you block or delete these Cookies you may not be able to use the application. These Cookies are not shared with any other application on your mobile device. We never use the Cookies from the mobile application to store personal information about you.

If you have questions or concerns regarding any information in this Privacy Policy, please contact us by email at . You can also contact us via our customer service at our Site.